The results fall into two findings: an increase in transmitted force and a more even distribution of that force across both body sides.
Finding 1 — increase in force
- without insole
- with Winsole
In all 9 pressure analyses an increase in force was measured. The increase averaged 58 N, with a minimum of 9 N and a maximum of 180 N. Not a single measurement showed a reduction in force.
| Measurement | without insole (N) | with Winsole (N) | difference (N) |
|---|---|---|---|
| 1 | 290 | 300 | +10 |
| 2 | 130 | 260 | +130 |
| 3 | 400 | 580 | +180 |
| 4 | 360 | 370 | +10 |
| 5 | 90 | 150 | +60 |
| 6 | 80 | 110 | +30 |
| 7 | 190 | 260 | +70 |
| 8 | 120 | 150 | +30 |
| 9 | 110 | 120 | +10 |
Finding 2 — symmetry
- without insole
- with Winsole
The optimum is reached when both feet apply an identical amount of force. Without an insole the deviation from this 50/50 distribution averages 7.4 N. With Winsole insoles the deviations are 1 N lower. The study concludes that an approximation to the ideal distribution can be achieved when the insoles are used.
Observed relationship
At higher pressure moments the force increase was also greater. The study interprets this as foot and knee joints having to stabilise particularly high pressure and compensate potential instabilities at high power output. This relationship was not conclusively quantified.
Summary of the study
- According to the study the relationship between absolute pressure level and the magnitude of the force increase is plausible, but it could not be conclusively quantified.
- The study names a dedicated target group analysis as a possible next step of investigation.
- The document contains no details on the number, age or gender distribution of the individual test participants — it only states that male and female cyclists of different performance classes were measured.
- The document names neither manufacturer nor model of the pressure measurement system used, and reports no statistical parameters such as significance level or standard deviation.
- The study contains no statements on watt figures, time savings, race results or medical effects.
Results in detail
- Power transferForce increase per measurement and the observed relationship with the pressure level.
- Left-right symmetryDeviation from the 50/50 distribution: 7.4 N without insole, 1 N less with Winsole.
- Pressure distributionThe pressure scans of Figure 3 and the concentration towards the big toe joint.
- Charts explainedFigures 1, 2 and 3 read step by step — axes, units and how to interpret them.